16 research outputs found

    Robotics and Artificial Intelligence in Gastrointestinal Endoscopy: Updated Review of the Literature and State of the Art

    Get PDF
    Abstract Purpose of Review Gastrointestinal endoscopy includes a wide range of procedures that has dramatically evolved over the past decades. Robotic endoscopy and artificial intelligence are expanding the horizons of traditional techniques and will play a key role in clinical practice in the near future. Understanding the main available devices and procedures is a key unmet need. This review aims to assess the current and future applications of the most recently developed endoscopy robots. Recent Findings Even though a few devices have gained approval for clinical application, the majority of robotic and artificial intelligence systems are yet to become an integral part of the current endoscopic instrumentarium. Some of the innovative endoscopic devices and artificial intelligence systems are dedicated to complex procedures such as endoscopic submucosal dissection, whereas others aim to improve diagnostic techniques such as colonoscopy. Summary A review on flexible endoscopic robotics and artificial intelligence systems is presented here, showing the m3ost recently approved and experimental devices and artificial intelligence systems for diagnosis and robotic endoscopy

    Switching from IFX originator to biosimilar CT-P13 does not impact effectiveness,safety and immunogenicity in a large cohort of IBD patients

    Get PDF
    Background: Switching from IFX originator to CT-P13 is safe; however, little data on immunogenicity exists. Research design and methods: Consecutive IBD patients on IFX originator were switched to CT-P13 and followed-up for 12 months. Clinical activity, infliximab trough levels (ITLs), anti-drug antibodies (ATIs), and adverse events were recorded at predefined timepoints (baseline, second CT-P13 infusion, 6 and 12 months). The outcomes investigated were immunogenicity, pharmacokinetics, effectiveness and safety. Results: 119 patients were switched to CT-P13 after a median time with IFX of 5.8 years. No changes in mean ITLs were observed. ATIs were detected in 30 patients (25.2%): 14 before and 16 after switch. Mean persistent ATIs were significantly higher compared to mean transient ones (109.74 ng/mL ±84.70 vs 18.22 ng/mL ±11.37, p < 0.001), with significantly lower ITLs associated (mean 0.32 µg/mL ±0.6 vs 3.08 µg/mL ±3.22, p < 0.001). A significant decrease of patients in steroid-fee clinical remission was observed after the switch (p = 0.004), with subsequent improvement at 6 months (p = 0.005). Eighteen patients (15.1%) discontinued IFX, only 6 (5%) for loss of response. Conclusions: Switching from infliximab originator to CT-P13 seems safe and effective, without differences in immunogenicity. A temporary reduction of clinical benefit after switching could be potentially explained by a ‘nocebo-effect response’

    Outpatient ESD for challenging colorectal lesions: Is it feasible and safe for western countries?

    No full text
    Background and study aims The need for hospital beds during the COVID-19 pandemic almost overwhelmed the health care systems all over the world. Therefore, elective non-life-saving procedures were postponed. We decided to perform all colorectal endoscopic mucosal dissections (ESDs) for challenging lesions as outpatient procedures, organizing an ad hoc path to management of any delayed post-procedural complications. The aim of the present study was to retrospectively evaluate the feasibility and safety of outpatient ESD for colorectal tumors. Patients and methods From March 2020 to May 2020, outpatient colorectal ESDs were performed for 15 challenging lesions. We retrospectively investigated feasibility and safety of the procedures, rates of en bloc resection, and complications rates. Results The mean age of the patients was 66.5 years and 40% of the them were on antiplatelet/anticoagulation therapy. Median size of removed lesions was 45mm (range 32-77) and 38mm (range 24 to 55) Five patients (33%) had rectal tumors extending to the dentate line and four (26.6%) were recurrences on a scar of previous endoscopic or surgical local resections. All complications, such as bleeding or visible microperforation, were managed endoscopically and no delayed perforations occurred. One patient had fever (37.5 degrees C), while three patients complained of anal pain after ESD for a rectal tumor that extended to the dentate line (RTDL); all patients were managed conservatively. Conclusion Outpatient colorectal ESD is feasible and safe for challenging lesions. It reduces costs of hospitalization but direct access to the endoscopy service to manage potential post-ESD complications should always be guaranteed

    Increasing the accuracy of colorectal cancer screening

    No full text
    IntroductionColorectal cancer (CRC) is a major health issue, being responsible for nearly 10% of all cancer-related deaths. Since CRC is often an asymptomatic or paucisymptomatic disease until it reaches advanced stages, screening is crucial for the diagnosis of preneoplastic lesions or early CRC.Areas coveredThe aim of this review is to summarize the literature evidence on currently available CRC screening tools, with their pros and cons, focusing on the level of accuracy reached by each test over time. We also provide an overview of novel technologies and scientific advances that are currently being investigated and that in the future may represent real game-changers in the field of CRC screening.Expert opinionWe suggest that best screening modalities are annual or biennial FIT and colonoscopy every 10 years. We believe that the introduction of artificial intelligence (AI)-tools in the CRC screening field could lead to a significant improvement of the screening efficacy in reducing CRC incidence and mortality in the future. More resources should be put into implementing CRC programs and support research project to further increase the accuracy of CRC screening tests and strategies
    corecore